Steel end bracket set completes both ends of the chain and allow for fastening on inner and outer radius.
Open guide channels must be used in all sliding applications. They must be installed on radius runway and are availabe in standard length of 2m. Ordering example for 4 meter channel: 4 sidewalls, 4(+1) joining and support sets and if present 4(+1) base profiles.
Guide channels with rollers must be used in all sliding applications on the opposite radius runway. Availabe in standard length of 2m. Ordering example for 4 meter channel: 4 sidewalls, 4 rollers sets, 4(+1) joining and support sets and if present 4(+1) base profiles.
Guide channels with polydur must be used in all sliding applications on the opposite radius runway. Availabe in standard length of 2m. Ordering example for 4 meter channel: 4 sidewalls, 4 polydur sets, 4(+1) joining and support sets and if present 4(+1) base profiles.
Guide channels with steel angle plate must be used in all sliding applications on the opposite radius runway. Availabe in standard length of 2m. Ordering example for 4 meter channel: 4 sidewalls, 4 angle plate sets, 4(+1) joining and support sets and if present 4(+1) base profiles .
For the correct functioning, the chain must lay on a flat surface. For this purpose ground channels have to be insalled on chain runway. Standard length from 100 mm to 2000mm, at multiple of 100mm. Upon request length up to 3000 mm can be delivered. In following fields please fill the requested sector length and the sector quantity needed.
Norms | Properties | Units | Dry | Conditioned |
---|---|---|---|---|
TERMICHE | ||||
DSC | Melting point (10° C/min.) | °C | ||
ASTM - D 696 | Coefficient of linear thermal expansion | X10-6 K-1 | ||
ASTM D 648 ISO 75 DIN 53461 |
Heat distortion temperature ISO 75 1.82 N/mm2 °C 210 DIN 53461 0.45 N/mm2 |
°C °C |
210 220 |
|
U. L. 94 | Flammability | H.B. | ||
IEC 695-2-1 | Incandescent wire Temperature °C 650 Thickness |
650 3 |
||
FLAMMABILITY | ||||
ASTM-D 257 | Volume resistivity | Ohm cm | 1015 | 1011 |
ASTM-D 257 | Surface resistivity | Ohm | 1013 | 1011 |
ASTM-D 149 | Dielectric strength | KV/mm | 22 | |
ASTM-D 150 | Dielectric constant (10 Hz) | - | 3.8 | 4.5 |
ASTM-D 150 | Dissipation factor (10Hz) | - | 0.02 | 0.09 |
PHYSICAL PROPERTIES |
||||
ASTM-D 792 | Density | g/cm3 | 1.38 | |
ASTM-D 570 | Water absorption at 23°C in water for 24 hours | % | 0.90 | |
MECHANICAL PROPERTIES | ||||
ASTM-D 638 ISO R/527 DIN 53455 |
Tensile yield stress Ultimate elongation |
N/mm2 % |
195 2.6 |
115 4 |
ASTM-D 638 ISO R/527 DIN 53457 |
Tensile modulus of elasticity | N/mm2 | 10600 | 6900 |
ASTM-D 790 ISO 178 DIN 53452 |
Flexural strength | N/mm2 | 310 | 190 |
ASTM-D 790 ISO 178 |
Flexural modulus | N/mm2 | 10500 | 6800 |
ASTM-D 256 | Unnotched Izod impact strength | J/m | 140 | 300 |
ISO 180/4C | Notched Izod impact strength | KJ/m2 | 110 | 125 |
ASTM-D 785 | Rockwell hardness | Scala R | 122 | 114 |
BRYLON 6 | BRYLON 6 | STEEL | ||
---|---|---|---|---|
Chemical agents | Concentration % | Amorphous | Crystal | |
Methyl acetate | 100 | RB3 | RB2 | RB |
Acetone | 100 | RB4 | RB | RB |
Acetic acid (aqueous solution) | 40 | AF | AF | AF |
Acetic acid (aqueous solution) | 10 | AF | AF | AF |
Acetic acid | AF | AF | AF | |
Citric acid | 10 | AD 15 | RD | AD |
Hydrochloric acid (aqueous solution) | 36 | S | S | S |
Hydrochloric acid (aqueous solution) | 10 | AF | AF | S |
Hydrochloric acid (aqueous solution) | 2 | AF | AD | S |
Chromic acid (aqueous solution) | 10 | AF | AF | AF |
Chromic acid (aqueous solution) | 1 | RD | RD | AF |
Hydrofluoric acid | 40 | AF | AF | S |
Formic acid (aqueous solution) | 85 S | S | AD | |
Formic acid (aqueous solution) | 40 S | AF | AF | AD |
Phosphoric acid (aqueous solution) | 10 | AF | AF | S |
Oleic acid | 100 | RB3 | RB3 | RD |
Sulphuric acid | 98 | S | S | S |
Sulphuric acid (aqueous solution) | 40 | AF | AF | S |
Sulphuric acid (aqueous solution) | 10 | AF | AF | S |
Sulphuric acid (aqueous solution) | 2 | AF | AD | S |
Tartaric acid (aqueous solution) | RD | RB | RD | |
Water | RB10 | RB9 | RD | |
Chlorine water | RD | RD | AD | |
Ethyl alcohol | 96 | RD17 | RB3 | RB |
Ammonia | 10 | RB11 | RB | AF |
Petrol | 100 | RB1 | RB | RB |
Bitumen | RD | RD | RB | |
Potassium carbonate | 100 | RB | RB | AF |
Sodium carbonate | 10 | RB10 | RB3 | AF |
Ammonium chloride (aqueous solution) | 10 | RB | RB | AF |
Calcium chloride (aqueous solution) | 20 | S | S | AF |
Calcium chloride (aqueous solution) | 10 | RB | RB | AF |
Sodium chloride | 10 | RB | RB | AF |
Formaldehyde (aqueous solution) | 30 | RD | RB | AD |
Fat | RB | RB | RB | |
Milk | RB | RB | RB | |
Mercury | RB | RB | RB | |
Oils | RB | RB | RB | |
Oil | RB | RB | RB | |
Paraffin oil | RB | RB | RB | |
Silicon oil | RB | RB | RB | |
Diesel oil | RB | RB | RB | |
Mineral oil | RB | RB | RB | |
Ozone | AF | AF | AF | |
Oil | RB | RB | RB | |
Potassium hydroxide (aqueous solution) | 10 | RB9 | RB3 | S |
Sodium hydroxide (aqueous solution) | 50 | RD | RD | S |
Sodium hydroxide (aqueous solution) | 10 | RB5 | RB | S |
Sodium hydroxide (aqueous solution) | 5 | RB9 | RB | S |
Aluminium sulphate | 10 | RB | RB | AF |
Soap (aqueous solution) | RB | RB | RB | |
Tincture of iodine | AF | AF | AD | |
Trichloroethylene | RD5 | RD4 | RB | |
Vaseline | RB | RB | RB |
Legend
The table shows the resistance to chemical agents of BRYLON 6 and Steel. The number by resistance value side shows which is the % weight increase due to swelling.
RB - Very good resistance.
RD - Good resistance.
AD - Limited resistance.
AF - Poor resistance.
S - Soluble.
Amorphous - Polymer in amorphous state.
Crystal - Polymer in crystalline state.
30091 | Nylon Cable Chain |
30092 | Nylon Cable Chain |
300A | Nylon cable chain with opening cross frames from inner radius |
300 | Nylon Cable Chain |
Temperature range: -30°C + 125°C