Slider

30LC

Steel cable chain with aluminum covers

  1. COM_STENDALTO_TESTO_360_GRADI
  2. Chain
  3. Separators
  4. End Brackets and Cable Clamps
  5. Guide Channels
  6. Materials

APPLICATION TYPE


Self Supported Stroke

Vertical Stroke

Main dimensions











Fixed end position

deter_a
deter_a
deter_a
deter_a
deter_a

Chain length calculation


























SEPARATION SYSTEM


Inner vertical separator

Inner separator with divisor roller

Vertical Separator

The vertical separator must be used to manage the inner space and set the proper space for each cable. Standard mounting every second pitch.

 
 
 
Please input the total quanity needed including
side separator, if present (in red).

ALUMINUM DIVISOR ROLLER

Symmetrical divisor roller

 
 
Divisor roller width: mm
Suitable for the chain:
Please input the total quanity needed including
side separator, if present (in red).

Vertical Separator

The vertical separator must be used to manage the inner space and set the proper space for each cable. Standard mounting every second pitch.

 
 
Please input the total quanity needed including
side separator, if present (in red).

APPLICATION TYPE


Self Supported Stroke

Vertical Stroke

MOUNTING POSITION


Position 1

Position 2

Position 3

STEEL END BRACKET SET

Steel end bracket set completes both chian ends and allow for fastening on outer radius and inner radius: mounting position must be specified. Stainless steel can be delivered on request.



End brackets set for

END BRACKETS

 
 

TIEWRAP CLAMP

 
 

STEEL CABLE CALMP

The steel cable clamps fasten the cable to the chain
Open the page

APPLICATION TYPE


Self Supported Stroke

Vertical Stroke

GUIDE CHANNEL


SINGLE CHAIN APPLICATION

DOUBLE OPPOSITE CHAIN APPLICATION

MATERIAL

Bright zinc plated
Stainless steel AISI 304
Stainless steel AISI 316
Alluminium

OPEN GUIDE CHANNEL

Open guide channels must be used in all sliding applications. They must be installed on radius runway and are availabe in standard length of 2m. Ordering example for 4 meter channel: 4 sidewalls, 4(+1) joining and support sets and if present 4(+1) base profiles.


A1 = mm; A2 = mm; H1 = mm; H2 = mm; S = mm;

Gude channel for chain
 
 
 

GUIDE CHANNEL WITH ROLLERS

Guide channels with rollers must be used in all sliding applications on the opposite radius runway. Availabe in standard length of 2m. Ordering example for 4 meter channel: 4 sidewalls, 4 rollers sets, 4(+1) joining and support sets and if present 4(+1) base profiles.


A1 = mm; A2 = mm; H1 = mm; H2 = mm; S = mm;

Gude channel for chain
 
 
 
 

GUIDE CHANNELS WITH POLYDUR BAR

Guide channels with polydur must be used in all sliding applications on the opposite radius runway. Availabe in standard length of 2m. Ordering example for 4 meter channel: 4 sidewalls, 4 polydur sets, 4(+1) joining and support sets and if present 4(+1) base profiles.


A1 = mm; A2 = mm; H1 = mm; H2 = mm; S = mm;

Gude channel for chain
 
 
 
 

GUIDE CHANNELS WITH STEEL ANGLE PLATE

Guide channels with steel angle plate must be used in all sliding applications on the opposite radius runway. Availabe in standard length of 2m. Ordering example for 4 meter channel: 4 sidewalls, 4 angle plate sets, 4(+1) joining and support sets and if present 4(+1) base profiles .


A1 = mm; A2 = mm; H1 = mm; H2 = mm; S = mm;

Gude channel for chain
 
 
 
 

GROUND CHANNEL

For the correct functioning, the chain must lay on a flat surface. For this purpose ground channels have to be insalled on chain runway. Standard length from 100 mm to 2000mm, at multiple of 100mm. Upon request length up to 3000 mm can be delivered. In following fields please fill the requested sector length and the sector quantity needed.


A5 = mm; H = mm; S = mm;

Gude channel for chain
 
 

BRYLON 6 TECHNICAL DATA

Norms Properties Units Dry Conditioned
TERMICHE
DSC Melting point (10° C/min.) °C    
ASTM - D 696 Coefficient of linear thermal expansion X10-6 K-1    
ASTM D 648
ISO 75
DIN 53461
Heat distortion temperature
ISO 75 1.82 N/mm2 °C 210
DIN 53461 0.45 N/mm2

°C
°C

210
220
 
U. L. 94 Flammability   H.B.  
IEC 695-2-1 Incandescent wire
Temperature °C 650
Thickness
 
650
3
 
FLAMMABILITY
ASTM-D 257 Volume resistivity Ohm cm 1015 1011
ASTM-D 257 Surface resistivity Ohm 1013 1011
ASTM-D 149 Dielectric strength KV/mm 22  
ASTM-D 150 Dielectric constant (10 Hz) - 3.8 4.5
ASTM-D 150 Dissipation factor (10Hz) - 0.02 0.09
PHYSICAL PROPERTIES
ASTM-D 792 Density g/cm3 1.38  
ASTM-D 570 Water absorption at 23°C in water for 24 hours % 0.90  
MECHANICAL PROPERTIES
ASTM-D 638
ISO R/527
DIN 53455
Tensile yield stress

Ultimate elongation
N/mm2

%
195

2.6
115

4
ASTM-D 638
ISO R/527
DIN 53457
Tensile modulus of elasticity N/mm2 10600 6900
ASTM-D 790
ISO 178
DIN 53452
Flexural strength N/mm2 310 190
ASTM-D 790
ISO 178
Flexural modulus N/mm2 10500 6800
ASTM-D 256 Unnotched Izod impact strength J/m 140 300
ISO 180/4C Notched Izod impact strength KJ/m2 110 125
ASTM-D 785 Rockwell hardness Scala R 122 114

CHEMICAL RESISTANCE

    BRYLON 6 BRYLON 6 STEEL
Chemical agents Concentration % Amorphous Crystal  
Methyl acetate 100 RB3 RB2 RB
Acetone 100 RB4 RB RB
Acetic acid (aqueous solution) 40 AF AF AF
Acetic acid (aqueous solution) 10 AF AF AF
Acetic acid   AF AF AF
Citric acid 10 AD 15 RD AD
Hydrochloric acid (aqueous solution) 36 S S S
Hydrochloric acid (aqueous solution) 10 AF AF S
Hydrochloric acid (aqueous solution) 2 AF AD S
Chromic acid (aqueous solution) 10 AF AF AF
Chromic acid (aqueous solution) 1 RD RD AF
Hydrofluoric acid 40 AF AF S
Formic acid (aqueous solution) 85 S S   AD
Formic acid (aqueous solution) 40 S AF AF AD
Phosphoric acid (aqueous solution) 10 AF AF S
Oleic acid 100 RB3 RB3 RD
Sulphuric acid 98 S S S
Sulphuric acid (aqueous solution) 40 AF AF S
Sulphuric acid (aqueous solution) 10 AF AF S
Sulphuric acid (aqueous solution) 2 AF AD S
Tartaric acid (aqueous solution)   RD RB RD
Water   RB10 RB9 RD
Chlorine water   RD RD AD
Ethyl alcohol 96 RD17 RB3 RB
Ammonia 10 RB11 RB AF
Petrol 100 RB1 RB RB
Bitumen   RD RD RB
Potassium carbonate 100 RB RB AF
Sodium carbonate 10 RB10 RB3 AF
Ammonium chloride (aqueous solution) 10 RB RB AF
Calcium chloride (aqueous solution) 20 S S AF
Calcium chloride (aqueous solution) 10 RB RB AF
Sodium chloride 10 RB RB AF
Formaldehyde (aqueous solution) 30 RD RB AD
Fat   RB RB RB
Milk   RB RB RB
Mercury   RB RB RB
Oils   RB RB RB
Oil   RB RB RB
Paraffin oil   RB RB RB
Silicon oil   RB RB RB
Diesel oil   RB RB RB
Mineral oil   RB RB RB
Ozone   AF AF AF
Oil   RB RB RB
Potassium hydroxide (aqueous solution) 10 RB9 RB3 S
Sodium hydroxide (aqueous solution) 50 RD RD S
Sodium hydroxide (aqueous solution) 10 RB5 RB S
Sodium hydroxide (aqueous solution) 5 RB9 RB S
Aluminium sulphate 10 RB RB AF
Soap (aqueous solution)   RB RB RB
Tincture of iodine   AF AF AD
Trichloroethylene   RD5 RD4 RB
Vaseline   RB RB RB

Legend
The table shows the resistance to chemical agents of BRYLON 6 and Steel. The number by resistance value side shows which is the % weight increase due to swelling.
RB - Very good resistance.
RD - Good resistance.
AD - Limited resistance.
AF - Poor resistance.
S - Soluble.
Amorphous - Polymer in amorphous state.
Crystal - Polymer in crystalline state.

next
prev

PERFORMANCES

Temperature range: -30°C + 125°C

HORIZONTAL SELF SUPPORTED STROKE:
Speed: 0,5 m/s
Acceleration: 2 m/s2

X = Self supported Maximum length (m)
Y = Added weight (kg/m)
VERTICAL STROKE:
Speed: 0,5 m/s
Acceleration: 2 m/s2

We use technical cookies and third party cookies to improve our services. By continuing to browse, you agree to the use of cookies. For further information or to find out how to change your settings and block cookies, please see our privacy policy.