Slider

BC417

Multicore control shielded signal cable with PUR jacket

Part
Number
Conductor n.
x section
Diameter
Ø
Bending
Radius
Copper
Weight
Cable
Weight
n x mm2 mm mm kg/km kg/km m
4170410 (4x(2x1))C 12,6 130 129,0 226,0
4170605 (6x(2x0,5))C 11,7 117 95,0 174,0
4170615 (6x(2x1,5)C)C 16,7 167 250,0 388,0
4170625 (6x(2x2,5))C 22,0 220 411,0 620,0
4170410W ((4X(2X1)C)C 16,5 165 119,0 365,0
4170405W (4x(2x0,5)C)C 14,5 145 125,0 278,0
4170605W (6x(2x0,5)C)C 16,5 165 150,0 297,0
4170615W (6x(2x1,5)C)C 21,0 210 339,0 670,0
4171207W (12X(2X0,75)C)C 25,0 188 343,0 780,0

Technical Data

Nominal Voltage Nominal Voltage
VDE DIN 0245 part. 102 Uo/U 450/750 V
UL AWM 1000 V
CSA AWM 1000 V
Testing Voltage Testing Voltage
2500 V
Speed Speed
240 m/min
Acceleration Acceleration
20 m/s2
Flame Resistance Flame Resistance
UL 1581 sect.1090
Oil resistance Oil resistance
VDE 0472 part 803/B
UL 1581
HD 22.10
EN 60811-2-1 (100°C x 16h)
UL/CSA Approval UL/CSA Approval
UL-AWM 80°C 1000 V
CSA AWM 75°C 1000 V FT1
NEK 606

Construction data

Conductor Conductor
High-flexible class 6 complying with: VDE 0295
IEC 60228
Insulation Insulation
polyolefine
Core assembling Core assembling
special multi-ply with soft strip
Outer Jacket Outer Jacket
PUR complying with standard UL/CSA
colour black
Shield Shield
tinned copper braid: >85%
Shield on pairs Shield on pairs
417…W tinned copper braid on each pairs, covering > 80%

Approvals

CE

Downloads

Technical Datasheet