Slider

BC450 Interbus Dynamic Application

Shielded BUS cable with PUR jacket

Part
Number
Conductor n.
x section
Diameter
Ø
Bending
Radius
Copper
Weight
Cable
Weight
n x mm2 mm mm kg/km kg/km m
4500005 (3x2x0,22)C 8,0 80 30,0 65,0

Technical Data

Characteristic Impedance Characteristic Impedance
100 Ohm +/- 15 Ohm
Electrical Resistance Electrical Resistance
96 Ohm/km
Insulation Resistance Insulation Resistance
> 5000 Mohm/km
Attenuation Attenuation
0,256 MHz=1,5 db/100 m
0,722 MHz=2,4 db/100 m
1 MHz=2,7 db/100 m
4 MHz=5,2 db/100 m
10 MHz=8,4 db/100 m
16 MHz=11,2 db/100 m
20 MHz=11,9 db/100 m
Near-end crosstalk Near-end crosstalk
0,722 MHz=61db/100m
1 MHz=59db/100m
2 MHz=55db/100m
4 MHz=50db/100m
8 MHz=46db/100m
10 MHz=44db/100m
16 MHz=41db/100m
20 MHz=40db/100m;
Speed Speed
240 m/min
Acceleration Acceleration
20 m/s2
Flame Resistance Flame Resistance
IEC 60332.1.1
UL/CSA Approval UL/CSA Approval
UL/CSA
DESINA
NEK 606

Construction data

Conductor Conductor
High-Flexible
Insulation Insulation
TPO
Core Identification Core Identification
DIN 47101
Outer Jacket Outer Jacket
PUR
purple colour RAL 4001
Shield Shield
tinned copper braid:> 80%

Approvals

CE

Downloads

Technical Datasheet

We use technical cookies and third party cookies to improve our services. By continuing to browse, you agree to the use of cookies. For further information or to find out how to change your settings and block cookies, please see our privacy policy.